Bitumen Products - Catagorized by Usage

you can click on product that you like to see full specification

Oxidized bitumen


Oxidized Bitumen or Blown bitumen grades are produced by passing air through the penetration grades. This process gives the bitumen more rubbery properties than its original formula and they are simply harder bitumen. Hard bitumen under controlled temperature conditions is widely used as an anti-slip layer compound in the piling industry, for the manufacture of roofing felts, the roofing and waterproofing industries, for sound dampening felts and under carriage sealant in the automotive industry, electric cable joint protection, joint filling compound, sealant compound and many others. Also used in sealing saw cuts and joints where expected movements are minimum. It is also used in the manufacturing of bituminous marine mastic for the oil & gas pipeline joints.

The most popular grades are; grades 95/25, 85/25, 90/40, and 115/15. We are also capable of producing other grades of Oxidized bitumen upon request by our customers. Oxidized Bitumen high softening temperatures qualify them as the excellent sealant for prevention from bleeding in high-temperature applications. Blown Grade Bitumen shall be broken up into small pieces (for the blown grade in molded cake form) and heated slowly to the application temperature of 220ºC to 230ºC. Oxidized Bitumen is predominantly used in the piling industry as an anti-slip compound for the manufacture of undercarriage sealants in the automobile industry. It is also used as a sealant compound, as a joint filling compound apart from being used in the manufacture of roofing felts and sound dampening felts. Further, Oxidized Bitumen is used in the manufacture of bituminous marine mastic, which is required for the oil and gas pipeline joints. This Oxidized Bitumen is available in different grades like 95/25, 85/25, 75/25, 90/40 and 115/15. Oxidized is also capable of producing other grades of Oxidized Bitumen according to the specifications of individual clients

Specifications


Analysis oxidized bitumen 115/15

Bitumen 115/15Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1010/20
Softening point °cASTM  D36°C110/120
Ductility @25 °cASTM  D113Cm1.5min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis bitumen 105/35

Bitumen 105/35Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1030/40
Softening point °cASTM  D36°C100/110
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.

Analysis oxidized bitumen 105/15

Bitumen 105/15Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM D5mm/1010/20
Softening point °cASTM D36°C100/110
Loss on heating(wt) %ASTM D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis bitumen 95/25

Bitumen 95/25Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM D5mm/1020/30
Softening point °cASTM D36°C90/100
Loss on heating(wt) %ASTM D6Wt. %0.2 max
Flashpoint °cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis asphalt 90/40

Bitumen 90/40Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1035/45
Softening point °cASTM  D36°C85/95
Ductility @25 °cASTM  D113Cm5.5min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis bitumen 90/15

Bitumen 90/15Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1010/20
Softening point °cASTM  D36°C85/95
Ductility @25 °cASTM  D113Cm1.5min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis asphalt 90/10

Bitumen 90/10Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/105/15
Softening point °cASTM  D36°C85/95
Ductility @25 °cASTM  D113Cm1.5min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.O.T102Negative

Analysis bitumen 85/40

Bitumen 85/40Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM D5mm/1035/40
Softening point °cASTM D36°C80/90
Ductility @25 °cASTM D113Cm3
Loss on heating(wt) %ASTM D6Wt. %0.2 max
Flashpoint cASTM D92°C260 min
Solubility is CS2(wt) %ASTM D4Wt. %99 min
Spot testA.A.S.H.O.T 102Negative

Analysis asphalt 85/35

Bitumen 85/35Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1030/40
Softening point °cASTM  D36°C80/90
Ductility @25 °cASTM  D113Cm1.5min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flash point °cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.T.O 102Negative

Analysis bitumen 85/25

Bitumen 85/25Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1020/30
Softening point °cASTM  D36°C80/90
Ductility @25 °cASTM  D113Cm3 min
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.O.T 102Negative

Analysis asphalt 75/35

Bitumen 75/35Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1030/40
Softening point °cASTM  D36°C70/80
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.T.O 102Negative

Analysis asphalt 75/25

Bitumen 75/25Test methodUnitSpecification
Specific gravity @25/25 CASTM D70(Kg/m3)1.05 approx.
Penetration @ 25°cASTM  D5mm/1020/30
Softening point °cASTM  D36°C70/80
Loss on heating(wt) %ASTM  D6Wt. %0.2 max
Flashpoint cASTM D92°C250 min
Solubility is CS2(wt) %ASTM  D4Wt. %99.5 max
Spot testA.A.S.H.T.O 102Negative

Bitumen 10

Bitumen 10 is the type of hard grade building asphalt with penetration starting from #10 that is why it is famous asphalt number 10. Bitumen No.10 is available in bag and drum also the bulk tanker. This grade of asphalt building material is mostly using in eastern Asia market especially Taiwan and China also Philippine and Indonesia.

Uses of bitumen #10

1. For underground moisture, waterproofing works
2. For nuclear power engineering, pipeline engineering, bottom anticorrosion, asphalt production of the production
3. For waterproofing membrane, moisture-proof paper production, etc.
4. For Anti-corrosion paint and waterproof production
5. Used for road and bridge caulking use

Datasheet of bitumen number 10

Technical indicators10
Penetration (25 ° C, 100 g, 5 s) / (0.1 mm)10-26
The ductility (25 ° C, 5 cm / min) / cm is not less than1.5
Softening point (ball method) / ℃ not less than95
Solubility (trichloroethylene) /% is not less than99.5
Evaporation loss (163 ° C, 5 h) /% no more than1
After evaporation, the penetration ratio (25 ℃) /% is not less than65
Flashpoint (open cup) / ℃ not less than230
Brittle / ℃report

 

Bitumen 30

Bitumen 30 is the soft grade of blown bitumen with softening point of 30+5 and softening point approx. 70C and it is available in bag and drum but in summer time it is risky to take it in the bag due to leakage of bitumen 30 inside of the container. Bitumen No.30 is producing by bitumen #60 and after heating up and lost 5% of total weight the first grade of oxidized bitumen is number 30.

Uses of bitumen #30

1. For underground moisture, waterproofing works
2. For nuclear power engineering, pipeline engineering, bottom anticorrosion, asphalt production of the production
3. For waterproofing membrane, moisture-proof paper production, etc.
4. For Anti-corrosion paint and waterproof production
5. Used for road and bridge caulking use

Datasheet of bitumen number 30

Technical indicators30
Penetration (25 ° C, 100 g, 5 s) / (0.1 mm)36-50
The ductility (25 ° C, 5 cm / min) / cm is not less than3.5
Softening point (ball method) / ℃ not less than60
Solubility (trichloroethylene) /% is not less than99.5
Evaporation loss (163 ° C, 5 h) /% no more than1
After evaporation, the penetration ratio (25 ℃) /% is not less than65
Flashpoint (open cup) / ℃ not less than230
Brittle / ℃report

 

Bitumen 40

Bitumen 40 is made by the extract of bitumen #60 and it is the very soft grade of oxidized asphalt that should be packed in the steel drum. It is flexible bitumen while the softening point is high.This type of asphalt is useful to use in road construction to keep the asphalt stable against hot season and movement.

Uses of bitumen #40

1. For underground moisture, waterproofing works
2. For nuclear power engineering, pipeline engineering, bottom anticorrosion, asphalt production of the production
3. For waterproofing membrane, moisture-proof paper production, etc.
4. For Anti-corrosion paint and waterproof production
5. Used for road and bridge caulking use

Datasheet of bitumen number 30

Technical indicators30
Penetration (25 ° C, 100 g, 5 s) / (0.1 mm)10-35
The ductility (25 ° C, 5 cm / min) / cm is not less than2.5
Softening point (ball method) / ℃ not less than75
Solubility (trichloroethylene) /% is not less than99.5
Evaporation loss (163 ° C, 5 h) /% no more than1
After evaporation, the penetration ratio (25 ℃) /% is not less than65
Flashpoint (open cup) / ℃ not less than230
Brittle / ℃report

 

Penetration Grade Bitumen


The penetration grade bitumen is refinery bitumen that is manufactured at different viscosities. The penetration test is carried out to characterize the bitumen, based on the hardness. Thus, it has the name penetration bitumen. The penetration bitumen grades range from 15 to 450 for road bitumen. But the most commonly used range is 25 to 200. This is acquired by controlling the test carried out i.e. the distillation process. The partial control of fluxing the residual bitumen with the oils can help in bringing the required hardness.

The BS EN 1426 and BS EN 1427 provides the penetration and softening point values for the respective grades, as from Table-1. This will help in identifying the equiviscosity and the hardness of the bitumen grade.

The grades are represented by the penetration values i.e. For example, 40/60 as a penetration value of 50 ± 10.

The BS EN 13303 also gives the measure of loss on heating with respective limits for all penetration bitumen grades. This measure is to ensure that there are no volatile components present.

So, no component whose loss will contribute to the setting and hardening of bitumen during its preparation or lay course is undergone. The BS EN 12592 provides the solubility values to ensure that there is less or no impurities in the bitumen material.


Specifications


Specification of bitumen penetration grade 30/40

Bitumen 30/40Test methodUnitSpecification
Specific gravity @ 25°cASTM D70Kg/cm31.01/1.06
Penetration @ 25°cASTM D5mm/1030/40
Softening point °cASTM D36°C55/63
Ductility @25 °cASTM D113cm100 min
Loss on heating(wt) %ASTM D6wt %0.2 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flash point °cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4wt %99.5 min
Spot testA.A.S.H.O.T102Negative

Specification of bitumen penetration grade 40/50

Bitumen 40/50Test methodUnitSpecification
Specific gravity @ 25°cASTM D70Kg/cm31.01/1.06
Penetration @ 25°cASTM D5mm/1040/50
Softening point °cASTM D36°C52/60
Ductility @25 °cASTM D113cm100 min
Loss on heating(wt) %ASTM D6wt %0.2 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flash point °cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4wt %99.5 min
Spot testA.A.S.H.O.T102Negative

Specification of bitumen penetration grade 60/70

Bitumen 60/70Test methodUnitSpecification
Specific gravity @ 25°CASTM D70Kg/cm31.01/1.06
Penetration @ 25°CASTM D5mm/1060/70
Softening point °CASTM D36°C49/56
Ductility @25 °CASTM D113cm100 min
Loss on heating(wt) %ASTM D6wt %0.2 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flashpoint °CASTM D92°C232 min
Solubility in TrichloroethyleneASTM D2042wt %99 min
Spot testA.A.S.H.O.T102Negative

Specification of bitumen penetration grade 80/100

Bitumen 80/100Test methodUnitSpecification
Specific gravity @ 25°cASTM D70Kg/cm31.01/1.06
Penetration @ 25°cASTM D5mm/1080/100
Softening point °cASTM D36°C42/50
Ductility @25 °cASTM D113cm100 min
Loss on heating(wt) %ASTM D6wt %0.2 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flash point °cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4wt %99.5 min
Spot testA.A.S.H.O.T102Negative

Specification of bitumen penetration grade 85/100

Bitumen 85/100Test methodUnitSpecification
Specific gravity @ 25°cASTM D70Kg/cm31.01/1.06
Penetration @ 25°cASTM D5mm/1085/100
Softening point °cASTM D36°C41/49
Ductility @25 °cASTM D113Cm100 min
Loss on heating(wt) %ASTM D6wt %0.2 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flash point cASTM D92°C250 min
Solubility is CS2(wt) %ASTM D4wt %99.5 min
Spot testA.A.S.H.O.T102Negative

Specification of bitumen penetration grade 120/150

Bitumen 120/150Test methodUnitSpecification
Specific gravity @ 25°CASTM D70Kg/m31000-1050
Penetration @ 25°CASTM D5mm/10120/150
Softening point °CASTM D36°C38 min
Ductility @25 °CASTM D113Cm100 min
Loss on heating(wt) %ASTM D6wt %0.5 max
Drop in penetration after heating %ASTM D5-D6%20 max
Flashpoint °CASTM D92°C218 min
Solubility in TrichloroethyleneASTM D2042wt %99 min
Spot testNegative

Specification of bitumen penetration grade 200/300

Bitumen 200/300Test methodUnitSpecification
Specific gravity @ 25°CASTM D70Kg/m3990-1040
Penetration @ 25°CASTM D5mm/10200/300
Softening point °CASTM D36°C32 min
Ductility @25 °CASTM D113cm100 min
Loss on heating(wt) %ASTM D6wt %1 max
Drop in penetration after heating %ASTM D5-D6%37 min
Flashpoint °CASTM D92°C177 min
Solubility in TrichloroethyleneASTM D2042wt %99 min
Spot testNegative

Specification of bitumen penetration grade 30/45

Bitumen 30/45Test methodUnitSpecification
Penetration @ 25°CIP 49mm/1030/45
Softening point °CIP 58°C52/60
Kinematic Viscosity @ 135⁰CIP 319mm2/s400 min
Flashpoint °CIP 36°C240 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 35/50

Bitumen 35/50Test methodUnitSpecification
Penetration @ 25°cIP 49Mm/1035/50
Softening point °cIP 58°C50/58
Kinematic Viscosity @ 135⁰CIP 370mm2/s400 min
Flash point°cIP 36°C240 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 40/60

Bitumen 40/60Test methodUnitSpecification
Penetration @ 25°cIP 49mm/1040/60
Softening point °cIP 58°C48/56
Kinematic Viscosity @ 135⁰CIP 370mm2/s325 min
Flash point°cIP 36°C230 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 50/70

Bitumen 50/70Test methodUnitSpecification
Penetration @ 25°cIP 49mm/1050/70
Softening point °cIP 58°C46/54
Kinematic Viscosity @ 135⁰CIP 370mm2/s295 min
Flash point°cIP 36°C230 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 70/100

Bitumen 70/100Test methodUnitSpecification
Penetration @ 25°CIP 49mm/1070/100
Softening point °CIP 58°C43/51
Kinematic Viscosity @ 135⁰CIP 370mm2/s230 min
Flash point °CIP 36°C225 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 100/150

Bitumen 100/150Test methodUnitSpecification
Penetration @ 25°cIP 49mm/10100/150
Softening point °cIP 58°C39/47
Kinematic Viscosity @ 135⁰CIP 370mm2/s175 min
Flashpoint °cIP 36°C230 min
Solubility is CS2(wt) %IP 47wt %99 min

Specification of bitumen penetration grade 160/220

Bitumen 160/220Test methodUnitSpecification
Penetration @ 25°cIP 49mm/10160/220
Softening point °cIP 58°C35/43
Kinematic Viscosity @ 135 °CIP 370mm2/s135 min
Flashpoint °cIP 36°C220 min
Solubility is CS2(wt) %IP 47wt %99 min

Bitumen emulsion


Bitumen is the oldest known thermoplastic material in use today. Its usefulness and appeal derive from its simple thermoplastic property of being a thin liquid at high temperature and a virtual solid at ambient temperature. For the vast majority of applications, bitumen is used in the temperature range 140 to 230°C at a viscosity of around 200 cSt (20 Pa.$). For many applications, these conditions are both essential and desirable allowing rapid throughput from hot bulk bitumen delivery through to final use without any reheating. There are limitations to the coating film thickness that can be achieved using hot-applied techniques and for some applications, it is necessary to apply at a lower temperature and/or viscosity. The reasons may be a combination of the process requirements, the application techniques, safety and environmental requirements or final product properties. The two methods used mostly to modify bitumen properties are emulsification with water and dilution with hydrocarbon solvent enabling the bitumen to be applied cold, up to about 80°C for emulsions or up to about 150°C for cutbacks, depending on the dilution and solvent used.

Specifications


PropertyProperty MinMaxTest MethodTest on EmulsionsViscosity, Saybolt Furol at 25 °C, SFS20100ASTM D244Storage stability test, 24-h, %–1ASTM D6930Particle charge testpositiveASTM D244Sieve test, %–0.1ASTM D6933Cement mixing test, % 2.0ASTM D6935Distillation:Residue, %57–ASTM D244Tests on residue from distillation test:Penetration, 25°C (77°F), 100 g, 5 s4090ASTM D5Ductility, 25°C (77°F), 5 cm/min, cm40–ASTM D113Solubility in trichloroethylene, %97.5–ASTM D2042

PropertyminmaxTest methodTest on emulsionsViscosity, Saybolt Furol at 50 °C, SFS50450ASTM D244Storage stability test, 24-h, %–1ASTM D6930Coating ability and water resistance:Coating, dry aggregateGoodASTM D244Coating, after sprayingFairASTM D244Coating, wet aggregateFairASTM D244Coating, after sprayingFairASTM D244Particle charge testPositiveASTM D244Sieve test, %–0.1ASTM D6933Distillation:Oil distillate, by volume of emulsion, %–12ASTM D6997Residue, %65–ASTM D244Tests on residue from distillation test:Penetration, 25°C (77°F), 100 g, 5 s100250ASTM D5Ductility, 25°C (77°F), 5 cm/min, cm40–ASTM D113Solubility in trichloroethylene, %97.5– ASTM D2042

PropertyminmaxTest methodTest on emulsionsViscosity, Saybolt Furol at 50 °C, SFS40450ASTM D244Storage stability test, 24-h, %–1ASTM D6930Coating ability and water resistance:Coating, dry aggregateGoodASTM D244Coating, after sprayingFairASTM D244Coating, wet aggregateFairASTM D244Coating, after sprayingFairASTM D244Particle charge testPositiveASTM D244Sieve test, %–0.1ASTM D6933Distillation:Oil distillate, by volume of emulsion, %–12ASTM D6997Residue, %65–ASTM D244Tests on residue from distillation test:Penetration, 25°C (77°F), 100 g, 5 s4090ASTM D5Ductility, 25°C (77°F), 5 cm/min, cm40–ASTM D113Solubility in trichloroethylene, %97.5– ASTM D2042

PropertyProperty MinMaxTest Method
Test on Emulsions
Viscosity, Saybolt Furol at 25 °C, SFS20100ASTM D244
Storage stability test, 24-h, %1ASTM D6930
Demulsibility, 35 mL, 0.8 % dioctyl sodium sulfosuccinate, %40ASTM D6936
Coating ability and water resistance:
Particle charge testPositiveASTM D244
Sieve test, %0.1ASTM D6933
Distillation : 
Oil distillate, by volume of emulsion, %3ASTM D6997
Residue, %60ASTM D244
Tests on residue from distillation test:
Penetration, 25°C (77°F), 100 g, 5 s100250ASTM D5
Ductility, 25°C (77°F), 5 cm/min, cm40ASTM D113
Solubility in trichloroethylene, %97.5ASTM D2042

 

PropertyProperty MinMaxTest MethodTest on EmulsionsViscosity, Saybolt Furol at 25 °C, SFS100400ASTM D244Storage stability test, 24-h, %–1ASTM D6930Demulsibility, 35 mL, 0.8 % dioctyl sodium sulfosuccinate, %40–ASTM D6936Coating ability and water resistance:Particle charge testPositiveASTM D244Sieve test, %–0.1ASTM D6933Distillation : Oil distillate, by volume of emulsion, %–3ASTM D6997Residue, %65–ASTM D244Tests on residue from distillation test:Penetration, 25°C (77°F), 100 g, 5 s100250ASTM D5Ductility, 25°C (77°F), 5 cm/min, cm40–ASTM D113Solubility in trichloroethylene, %97.5–ASTM D2042

Technical Data Sheet of Cationic Bitumen Emulsion K1-40

NoPropertyTest MethodMinMax
1Saybolt fural viscosity @ 25?C secASTM D22425
2Storage Stability (24 hours) %ASTM D2241
3Sieve Test (%)ASTM D2240.1
4Particle Charge TestASTM D224Positive
5Solubility in Trichloroethylene (% Mass)ASTM D204297.5
6Residue from distillationASTM D22437
7Penetration @ 25?C, 100g, 5secASTM D560200

Technical Data Sheet of Cationic Bitumen Emulsion K1-60

NoPropertyResult
1Particle chargePos.
2Residue on 710 um KS sieve (%)(m/m), maximum0.05
3Residue on 150 um KS sieve (g per 100 mL), maximum0.15
4Binder content (%)(m/m), minimum57
5Viscosity (degrees Engler (°E) at 20°C6-9
6Viscosity redwood No. II (s at 85°C)
7Storage stability (long period test) % water content difference, maximum2

Technical Data Sheet of Cationic Bitumen Emulsion K1-70

NoPropertyResult
1Particle chargePos.
2Residue on 710 um KS sieve (%)(m/m), maximum
3Residue on 150 um KS sieve (g per 100 mL), maximum
4Binder content (%)(m/m), minimum67
5Viscosity (degrees Engler (°E) at 20°C
6Viscosity redwood No. II (s at 85°C)25-35
7Storage stability (long period test) % water content difference, maximum

Technical Data Sheet of Cationic Bitumen Emulsion K2

NoPropertyResult
1Particle chargePos.
2Residue on 710 um KS sieve (%)(m/m), maximum0.05
3Residue on 150 um KS sieve (g per 100 mL), maximum0.15
4Binder content (%)(m/m), minimum57
5Viscosity (degrees Engler (°E) at 20°C10 max
6Viscosity redwood No. II (s at 85°C)
7Storage stability (long period test) % water content difference, maximum2

Technical Data Sheet of Cationic Bitumen Emulsion K3

NoPropertyResult
1Particle chargePos.
2Residue on 710 um KS sieve (%)(m/m), maximum0.05
3Residue on 150 um KS sieve (g per 100 mL), maximum0.15
4Binder content (%)(m/m), minimum57
5Viscosity (degrees Engler (°E) at 20°C10 max
6Viscosity redwood No. II (s at 85°C)
7Storage stability (long period test) % water content difference, maximum2

Cutback Bitumen


Cutback bitumen is a range of binders that are produced by blending (mixing) penetration grade bitumen and a hydrocarbon solvent, such as paraffin or mineral turpentine.

When the solvent has evaporated, the binder returns to its original penetration grade to tie the particles together. Cutback bitumen gets its name from the solvent that is involved in the process, because the solvent "cuts back" or evaporates, leaving behind the binder to "get on with the job". The solvent used in cutback bitumen is called the "cutter" or "flux".

Three types of solvents are used for the blending process: slow-curing, medium-curing or rapid-curing solvents. The latter two are the most common in South Africa. The choice of the solvent determines the rate at which the bitumen will cure when exposed to air. A rapid-curing (RC) solvent will evaporate faster than a medium-curing (MC) solvent. Curing relates to the evaporation rate of the solvent which influences the setting time of the bitumen. The viscosity of the cutback bitumen is determined by the proportion of solvent added: the higher the proportion of solvent, the lower the viscosity of the cutback.

Cutbacks differ from penetration grade bitumen in that they are more workable — in other words, they can be more easily reshaped. Less heat is required to liquefy cutback bitumen than penetration bitumen, making it easier to use at lower temperatures.

Typical cutback bitumens are MC 30 and RC 250. The letters in the name refer to the curing action of the solvent, and the number to the viscosity of the binder.

Specifications


guarantees that the Rapid curing Cut Back Grade RC-70 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST70140ASTM D2170
Flash point(tag open cup), °c —ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f(360°c)
to 437°f(225°c)
To 500°f(260°c)
to 600°f(316°c)
Residue from distillation to
680°f(360°c), percent volume by difference
50ASTM D402
70
85
55
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100 —ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume —0.2ASTM D95

 guarantees that the Rapid curing CutBack Grade RC-250 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028–97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST250500ASTM D2170
Flashpoint(tag open cup), °c 27ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f (360°c)
to 437°f(225°c)
To 500°f(260°c)
to 600°f(316°c)
Residue from distillation to
680°f(360°c), percent volume by difference
35ASTM D402
60
 80
65
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume —0.2ASTM D95

guarantees that the Rapid curing CutBack Grade RC-800 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST8001600ASTM D2170
Flashpoint(tag open cup), °c 27ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°f (360°c)
to 437°f(225°c)
To 500°f(260°c)
to 600°f(316°c)
Residue from distillation to
680°f(360°c), percent volume by difference
 15ASTM D402
 45
75
75 —
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume0.2ASTM D95

 guarantees that the Rapid curing CutBack Grade RC-3000 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST30006000ASTM D2170
Flashpoint(tag open cup), °c —27ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F(360°F)
to 437°f(225°c)
To 500°f(260°c)
to 600°f(316°c)
Residue from distillation to
680°f(360°c), percent volume by difference
ASTM D402
25
70
80 —
Test on Residue from distillation test
Penetration 77°f(25°c) 100g,5s mm80120ASTM D5
Ductility 77°f(25°c) 5cm/min cm100ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume0.2ASTM D95

guarantees that the Medium Curing CutBack Grade MC-30 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST3060ASTM D2170
Flash point(tag open cup), °C38ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F (360°C)
to 437°F (225°C)
To 500°F (260°C)
to 600°F (316°C)
Residue from distillation to
680°F(360°C), percent volume by difference
25 

ASTM D402

 

3075
7595
50
Test on Residue from distillation test
Viscosity at 140°F (60°C)30120ASTM D2170
Penetration 77°F (25°C) 100g,5s mm120300ASTM D5
Ductility 77°F (25°C) 5cm/min cm100ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume0.2ASTM D95

 guarantees that the Medium Curing CutBack Grade MC-70 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C ,cST70140ASTM D2170
Flashpoint(tag open cup), °C38ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F (360°C)
to 437°F (225°C)
to 500°F (260°C)
to 600°F (316°C)
Residue from distillation to
680°F (360°C), percent volume by difference
 —20ASTM D402

 

1070
6593
55
Test on Residue from distillation test
Viscosity at 140°F (60°C)30120ASTM D2170
Penetration 77°F (25°C) 100g,5s mm120300ASTM D5
Ductility 77°F (25°C) 5cm/min cm100ASTM D113
Solubility in trichloroethylene %99ASTM D2042
Water, percent volume —0.2ASTM D95

 guarantees that the Medium Curing CutBack Grade MC-250 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST250500ASTM D2170
Flashpoint (tag open cup), °C66ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F (360°C)
to 437°F (225°C)
To 500°F (260°C)
to 600°F (316°C)
Residue from distillation to
680°F (360°C), percent volume by difference
20 

ASTM D402

 

555
6090
67
Test on Residue from distillation test
Viscosity at 140°f(60°C)30120ASTM D2170
Penetration 77°F (25°C) 100g,5s mm120300ASTM D5
Ductility 77°F (25°C) 5cm/min cm100 —ASTM D113
Solubility in trichloroethylene %99 —ASTM D2042
Water, percent volume0.2ASTM D95

guarantees that the Medium Curing CutBack Grade MC-800 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028–97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C ,cST8001600ASTM D2170
Flashpoint(tag open cup), °C66ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F (360°C)
to 437°F (225°C)
To 500°F (260°C)
to 600°F (316°C)
Residue from distillation to
680°F (360°C), percent volume by difference
 — 

ASTM D402

 

 —40
4585
75 —
Test on Residue from distillation test
Viscosity at 140°F (60°C)30120ASTM D2170
Penetration 77°F (25°C) 100g,5s mm120250ASTM D5
Ductility 77°F (25°C) 5cm/min cm100 —ASTM D113
Solubility in trichloroethylene %99 —ASTM D2042
Water, percent volume —0.2ASTM D95

 guarantees that the Medium Curing CutBack Grade MC-3000 it supplies under its offers is produced in compliance to and is in conformity to ASTM D-2028-97 Rev 2004 and is compliant to the following specification requirements.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°c ,cST30006000ASTM D2170
Flashpoint(tag open cup), °c66ASTM D3143
Distillation test
Distillate, volume percent of total Distillate to 680°F (360°C)
to 437°F (225°C)
to 500°F (260°C)
to 600°F (316°C)
Residue from distillation to
680°F (360°C), percent volume by difference
 — 

ASTM D402

 

15
1575
80 —
Test on Residue from distillation test
Viscosity at 140°F (60°C)30120ASTM D2170
Penetration 77°F (25°C) 100g,5s mm120300ASTM D5
Ductility 77°F (25°C) 5cm/min cm100 —ASTM D113
Solubility in trichloroethylene %99 —ASTM D2042
Water, percent volume0.2ASTM D95

 guaranty the quality of cutback SC-70 with the arrangement of the international inspectors to check quality and quantity of the bitumen on each shipment during the loading to vessel and controlling the production by QC team via batch test report before shipping. RABIT guaranty the quality to meet with ASTM/EN 15322:2009

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C [140°F], mm2/s70140ASTM D2170
Flashpoint(Cleveland open cup), °C [°F] 60 —ASTM D92
distillate test
Total distillate to 360°C [680°F], volume %35ASTM D402
Solubility, %95ASTM D2024
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s200 7000ASTM D2170
Asphalt residue:
Residue of 100 penetration, %40ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm50ASTM D113
Water, %0.5ASTM D95

. guaranty the quality of cutback SC-250 with the arrangement of the international inspectors to check quality and quantity of the bitumen on each shipment during the loading to vessel and controlling the production by QC team via batch test report before shipping. RABIT guaranty the quality to meet with ASTM/EN 15322:2009.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C [140°F], mm2/s250500ASTM D2170
Flashpoint(Cleveland open cup), °C [°F] 60 —ASTM D92
distillate test
Total distillate to 360°C [680°F], volume %25ASTM D402
Solubility, %95ASTM D2024
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s400 10000ASTM D2170
Asphalt residue:
Residue of 100 penetration, %50ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm50ASTM D113
Water, %0.5ASTM D95

 guaranty the quality of cutback SC-800 with the arrangement of the international inspectors to check quality and quantity of the bitumen on each shipment during the loading to vessel and controlling the production by QC team via batch test report before shipping. RABIT guaranty the quality to meet with ASTM/EN 15322:2009.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C [140°F], mm2/s8001600ASTM D2170
Flashpoint(Cleveland open cup), °C [°F] 70 —ASTM D92
distillate test
Total distillate to 360°C [680°F], volume %15ASTM D402
Solubility, %95ASTM D2024
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s1000 16000ASTM D2170
Asphalt residue:
Residue of 100 penetration, %60ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm50ASTM D113
Water, %0.5ASTM D95

 guaranty the quality of cutback SC-3000 with the arrangement of the international inspectors to check quality and quantity of the bitumen on each shipment during the loading to vessel and controlling the production by QC team via batch test report before shipping. RABIT guaranty the quality to meet with ASTM/EN 15322:2009.

propertyspecification limit Test method
MinMax
Kinematic viscosity at 60°C [140°F], mm2/s30006000ASTM D2170
Flashpoint(Cleveland open cup), °C [°F] 70 —ASTM D92
distillate test
Total distillate to 360°C [680°F], volume %8ASTM D402
Solubility, %95ASTM D2024
Kinematic viscosity on distillation residue at 60°C [140°F], mm2/s2000 35000ASTM D2170
Asphalt residue:
Residue of 100 penetration, %75ASTM D243
Ductility of 100 penetration residue at 25°C [77°F], cm50ASTM D113
Water, %0.5ASTM D95

Bitumen Coating


Bitumen coating compositions having substantially improved application and drying properties and producing coatings of improved properties including resistance to ultraviolet rays and alligatoring resulting therefrom said coating compositions comprising volatile solvent solutions of a bitumen coating material having softening point between 110 F To 250 F. The bitumen coating are also characteristically non-viscous materials which are not thixotropic and are therefore ordinarily applied as thin films. The bitumen coating compositions may also contain filler materials which tend to settle from the non-thixotropic compositions after storage for only a short time. It has been proposed in the past to add inert colloidal fillers such as silica to obtain thixotropic properties and thicker films on the application of the compositions. However, even such inert fillers tend to affect only solution properties and generally exist in the finished coating as an expensive additive which does not benefit other properties of the coating.

Specifications


Specification of  Iso Polymer Bitumen

Softening Point90-95°C
ElongationOver 400%
Flash PointOver 250°C
Scroll to Top